COMPARISON OF TOTAL CHOLESTEROL LEVELS IN SAMPLES SERUM TO BE CHECKED IMMEDIATELY AND SERUM SAMPLE WHICH WAS POSTPONED FOR 7 DAYS IN THE REFRIGERATOR WITH A TEMPERATURE OF 2-8°C AT BHAYANGKARA HOSPITAL

Penulis

  • Sri Miranda Maku Universitas Bina Mandiri Gorontalo
  • Muh. Rizman Naim Universitas Bina Mandiri Gorontalo
  • Laras Puspita Taib Universitas Bina Mandiri Gorontalo

DOI:

https://doi.org/10.47918/kdv97t04

Kata Kunci:

total cholesterol; serum storage; pre-analytical phase; refrigerated storage; laboratory analysis.

Abstrak

Total cholesterol measurement is an essential laboratory examination for assessing cardiovascular risk and monitoring lipid metabolism. However, immediate analysis is not always feasible in routine clinical practice, making refrigerated storage a common pre-analytical procedure. This study aimed to compare total cholesterol levels between serum samples analyzed immediately after collection and serum samples stored at 2–8°C for seven days. A quantitative analytical observational study with a repeated-measurement comparative design was conducted at Bhayangkara Hospital, Gorontalo, Indonesia, from June to July 2025. Fifteen paired serum samples were selected using accidental sampling. Total cholesterol concentrations were measured using the BioSystem BA200 automated chemistry analyzer. Differences between immediate and delayed analyses were evaluated using the paired-samples t-test after confirmation of data normality. Of the 15 samples, seven (47%) had normal cholesterol levels and eight (53%) had abnormal levels. The mean total cholesterol concentration increased slightly from 203 mg/dL to 206 mg/dL after seven days of refrigerated storage. However, the paired-samples t-test showed no statistically significant difference between the two conditions (p = 0.052). These findings indicate that serum storage at 2–8°C for up to seven days maintains total cholesterol stability and can be considered an acceptable pre-analytical practice when immediate laboratory analysis is not feasible.

Referensi

[1] J. Cai, R. Chen, S. Yi, and M. Hu, “Challenges and strategies in laboratory blood lipid detection,” Chinese J. Lab. Med., vol. 48, no. 7, pp. 814–818, 2025, doi: 10.3760/cma.j.cn114452-20241023-00581.

[2] A. Pottle, “Measuring cholesterol levels.,” Nurs. Stand., vol. 21, no. 46, pp. 42–47, 2007, [Online]. Available: https://www.scopus.com/inward/record.uri?eid=2-s2.0-34748855842&partnerID=40&md5=b470177ae0a47fb78d27f3b147b59ad4

[3] K. Yun, J. Choi, I.-U. Song, and Y.-A. Chung, “Smartphone-based point-of-care cholesterol blood test performance evaluation compared with a clinical diagnostic laboratory method,” Appl. Sci., vol. 9, no. 16, 2019, doi: 10.3390/app9163334.

[4] L. Lee and W. Rankin, “Preparation for blood tests: what can go wrong before the sample reaches the lab,” Aust. Prescr., vol. 48, no. 4, pp. 122–127, 2025, doi: 10.18773/austprescr.2025.034.

[5] G. Lombardi, P. Lanteri, A. Colombini, and G. Banfi, “Blood biochemical markers of bone turnover: Pre-analytical and technical aspects of sample collection and handling,” Clin. Chem. Lab. Med., vol. 50, no. 5, pp. 771–789, 2012, doi: 10.1515/cclm-2011-0614.

[6] C. Oddoze, E. Lombard, and H. Portugal, “Stability study of 81 analytes in human whole blood, in serum and in plasma,” Clin. Biochem., vol. 45, no. 6, pp. 464–469, 2012, doi: 10.1016/j.clinbiochem.2012.01.012.

[7] Y. C. Megerssa and F. R. Gari, “Pre-analytical stability of selected biochemical analytes in serum of horses and oxen stored at −20°C,” Vet. Med. Sci., vol. 10, no. 2, 2024, doi: 10.1002/vms3.1368.

[8] M. Marashifard, H. Vakilpour, Z. Sayadi, H. Sadeghi, A. Fatemi, and K. Jahanbin, “The Effect of Delay in Serum Separation on the Results of Biochemical Tests,” J. Isfahan Med. Sch., vol. 41, no. 729, pp. 624–630, 2023, doi: 10.48305/jims.v41.i729.0624.

[9] V. Muzakova, P. K. Beekhof, and E. H. J. M. Jansen, “Very long-term stability of lipid biomarkers in human serum,” Anal. Biochem., vol. 597, 2020, doi: 10.1016/j.ab.2020.113695.

[10] J. Zhou et al., “The stability of 65 biochemistry analytes in plasma, serum, and whole blood,” Clin. Chem. Lab. Med., vol. 62, no. 8, pp. 1557–1569, 2024, doi: 10.1515/cclm-2023-1192.

[11] H. Gylling and T. A. Miettinen, “Drug-induced effects on cholesterol catabolism and bile acids,” Curr. Opin. Investig. Drugs, vol. 7, no. 3, pp. 214–218, 2006, [Online]. Available: https://www.scopus.com/inward/record.uri?eid=2-s2.0-33644955931&partnerID=40&md5=09b5fe0c608b19108a475597beb6765d

[12] L. Baskin, A. Chin, A. Abdullah, and C. Naugler, “Errors in patient preparation, specimen collection, anticoagulant and preservative use: how to avoid such pre-analytical errors,” in Accurate Results in the Clinical Laboratory: A Guide to Error Detection and Correction, Second Edition, University of Calgary, Calgary Laboratory Services, Calgary, AB, Canada: Elsevier, 2019, pp. 11–26. doi: 10.1016/B978-0-12-813776-5.00002-9.

[13] M. Dajak, “Preanalytical phase of clinical-diagnostic process,” Jugosl. Med. Biohemija, vol. 24, no. SUPPL. 4, pp. 23–33, 2005, [Online]. Available: https://www.scopus.com/inward/record.uri?eid=2-s2.0-22144482382&partnerID=40&md5=285b4472ea4cc2be622656b0710722fd

[14] T. Kouri et al., “Pre-analytical factors and measurement uncertainty,” Scand. J. Clin. Lab. Invest., vol. 65, no. 6, pp. 463–476, 2005, doi: 10.1080/00365510500208332.

[15] H. Sadrzadeh, L. Baskin, and G. Kline, “Variables affecting endocrine tests results, errors prevention and mitigation,” in Endocrine Biomarkers: Clinicians and Clinical Chemists in Partnership, Department of Pathology and Laboratory Medicine and Graduate Studies, University of Calgary, Calgary, AB, Canada: Elsevier Inc., 2017, pp. 1–40. doi: 10.1016/B978-0-12-803412-5.00001-X.

[16] C. F. Y. Flores, Á. De las Mercedes Hurtado Pineda, V. M. C. Bonilla, and K. Sáenz-Flor, “Sample management: Stability of plasma and serum on different storage conditions,” Electron. J. Int. Fed. Clin. Chem. Lab. Med., vol. 31, no. 1, pp. 46–55, 2020, [Online]. Available: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85091045255&partnerID=40&md5=acc0ea7853632e78976a4339306cc240

[17] L. Pawlik-Sobecka et al., “The influence of serum sample storage conditions on selected laboratory parameters related to oxidative stress: A preliminary study,” Diagnostics, vol. 10, no. 1, 2020, doi: 10.3390/diagnostics10010051.

[18] A. C. Adhikari, H. H. Peiris, and A. P. Attanayake, “Stability of Serum Total Cholesterol, Triglycerides, and Plasma Glucose of Healthy Individuals at Different Storage Conditions,” Ceylon J. Sci., vol. 53, no. 3, pp. 435–438, 2024, doi: 10.4038/cjs.v53i3.8294.

[19] C. N. França, C. C. Mendes, and C. E. S. Ferreira, “Time collection and storage conditions of lipid profile,” Brazilian J. Med. Biol. Res., vol. 51, no. 3, 2018, doi: 10.1590/1414-431X20176955.

[20] R. E. Gislefoss, T. K. Grimsrud, and L. Mørkrid, “Long-term stability of serum components in the Janus Serum Bank,” Scand. J. Clin. Lab. Invest., vol. 68, no. 5, pp. 402–409, 2008, doi: 10.1080/00365510701809235.

[21] Y. Shimizu and K. Ichihara, “Elucidation of stability profiles of common chemistry analytes in serum stored at six graded temperatures,” Clin. Chem. Lab. Med., vol. 57, no. 9, pp. 1388–1396, 2019, doi: 10.1515/cclm-2018-1109.

[22] F. Razi et al., “Stability of thirty-four analytes in blood samples of diabetic patients,” Clin. Lab., vol. 66, no. 1–2, pp. 43–49, 2020, doi: 10.7754/Clin.Lab.2019.190514.

[23] N. Chaudhry, A. Hayat, T. M. Ahmad, N. Majeed, S. Israr, and A. Saddique, “EFFECT OF DELAYED CENTRIFUGATION ON SERUM CHEMISTRY,” Pakistan Armed Forces Med. J., vol. 69, no. 3, pp. 595–599, 2019, [Online]. Available: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85140018419&partnerID=40&md5=bf94c0526a2d68611e0919054131253a

Diterbitkan

2026-06-30

Cara Mengutip

COMPARISON OF TOTAL CHOLESTEROL LEVELS IN SAMPLES SERUM TO BE CHECKED IMMEDIATELY AND SERUM SAMPLE WHICH WAS POSTPONED FOR 7 DAYS IN THE REFRIGERATOR WITH A TEMPERATURE OF 2-8°C AT BHAYANGKARA HOSPITAL. (2026). Journal of Health, Technology and Science (JHTS), 7(2), 106-117. https://doi.org/10.47918/kdv97t04