COMPARISON OF TOTAL BILIRUBIN LEVELS IN SERUM WITHOUT LIGHT EXPOSURE DELAYED FOR 1 HOUR AND 3 HOURS

  • niluh yuniwarsiti universitas bina mandiri gorontalo, indonesia
  • Rizman Naim Bina Mandiri University Gorontalo
  • Laras Puspita Taib Bina Mandiri University Gorontalo

Abstrak

The total bilirubin test is one of the laboratory tests to determine the function of the liver and bile ducts. Impaired liver function can be shown by hemolytic anemia, liver cirrhosis, hepatitis, and hepatitis carcinoma. This study aims to determine the comparison of total bilirubin levels in serum without light exposure that is delayed for 1 hour and 3 hours. The method in this study uses a quantitative approach with a type of experimental research  of Cross sectional design. The types of data used are primary data and secondary data. The sampling technique uses the purposive sampling technique, with a sample number of 10 samples. The results showed that the average value of total bilirubin examination in serum (immediately checked) with  an average result value of 0.514 mg/dL, while in serum it was delayed for 1 hour with an average result of 0.513 mg/dL and serum was delayed for 3 hours with an average value of 0.511 mg/dL and the result of the value (significance) > from alpha (0.05) or (sig > 0.05) then Ho was accepted and Ha was rejected which means There was no difference in the results of total bilirubin levels in serum without light exposure that was delayed by 1 hour and 3 hours.

Referensi

[1] Fadhilah F, Sari A.B and Muhammad F. (2019). Effect of exposure duration on total bilirubin levels of diazo colorimetric method. Journal of Clinical Health Analyst Science 7 (1)
[2] Fang B, Card P.D, Chen J, Li L, Laughlin T, Jarrold B, Zhao W, Benham A.M, Maatta A.T, Hawkins T.J dan Hakozaki T. (2022). A Potential Role of Keratinocyte-Derived Bilirubin in Human Skin Yellowness and Its Amelioration by Sucrose Laurate/Dilaurate.International Journal Of Molecular Sciences Vol.23
[3] Kirnanoro and Maryana, (2020).Physiological Anatomy. Yogyakarta: Pustaka Baru Press
[4] Labir, K., Sulisnadewi and Gumilar (2014), Phototherapy with Decreased Blood Bilirubin Levels in BBLR Infants with Hyperbilirubinemia.pp. 0-4. Availabel at: http://poltekkes-denpasar.ac.id/files/ Jurnal Gema Kenursing/June 2014/Ketut Labir,dkk.pdf.
[5] Latief, J. (2018). Overview of the results of the total bilirubin examination in fresh serum and serum that was left for 3 hours at Toto Kabila Hospital, Bone Bolango Regency in 2018. (Scientific paper) DIII Health Analyst Study Program. Stikes Bina Mandiri Gorontalo. Gorontalo.
[6] Lestari N.PH, (2019). Difference in Total Bilirubin Serum Levels Examined Immediately and Those Stored at a Temperature of 2-8°C. (Scientific Paper) Poltekkes of the Ministry of Health Denpasar.
[7] Permenkes, R. I. (2013). Regulation of the Minister of Health of the Republic of Indonesia Number 43 of 2013 concerning How to Implement Good Clinical Laboratories. Jakarta: Ministry of Health of the Republic of Indonesia.
[8] Rahmawati., Rustiah, W., Rauf, D., & Rais, K. (2023). Overview of Total Bilirubin Level Examination in Alcoholic Beverage Consumers. Journal of Health Analyst Media, 14(1), 1-9.
[9] Rosida A. (2016). Laboratory examination of liver diseases. Periodical Medicine, Vol.12, No.1, 123-131
[10] Rusady, D.O. (2022). Effect of 3 Hour Delay Time on Total Bilirubin Levels in Serum (Doctoral dissertation, Binawan University).
[11] Sari D.W, Kesuma S and Kusumawati N. (2023). Analysis of Total Bilirubin Examination Based on Variation in Lamp Light Exposure Time on Specimens. Journal of Science and Health Vol.2, No.2 November (p.71−77)
[12] Suaryanti I.G.A.P, Resnhaleksmana E., Fihirudin, Zaetun S and Khusuma A. (2023).Effect of type of anticoagulant on the results of bilirubin level examination directly by the jendrassik-grof method. Scientific Journal of Pharmacy Vol. 15, No. 1
[13] Sugiatmini, S., and Aisy, L. R. (2022). Comparison of total bilirubin levels in fresh serum and serum stored for 24 hours at a temperature of 2-8° C with carbon paper using the grof general method. Journal of Biological Analysis, 6(01).
Diterbitkan
2024-06-20